If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TRUMPower DESCRIPTION 37.5-64 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES TMC60 SERIES The TMC60 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 37.5-64 watts of continuous output power at convection cooling. They operate at 90-264 VAC input voltage without the need of voltage selection, and are suited for medical, information technology and industrial applications. Approval to both EN 60601-1 and EN 60950-1 safety standards improves design-in time and reduces end equipment compliance costs. FEATURES Medical and ITE approvals Compact size 2" x 4" x 1.18" Single, dual and triple outputs F u l l r a n g e i n p u t 9 0 - 2 6 4 VA C Low earth leakage current Level B emissions RoHS compliant SAFETY STANDARD APPROVALS UL 60601-1 CSA C22.2 No. 601.1 INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Earth leakage current: 90-264 VAC 47-63 Hz 1.3 A (rms) for 100 VAC 0.7 A (rms) for 240 VAC 150 A max. @ 264 VAC, 60 Hz TUV EN60601-1 GENERAL SPECIFICATIONS Switching frequency: Efficiency: 625 KHz 80-88% typical except TMC60-T31-3 and TMC60-T31-5 at 75% typical Hold-up time: Line regulation: Inrush current: Withstand voltage: 12 msec minimum at 110 VAC 0.5% maximum at full load 30 A @ 115 VAC, or 60 A @ 230 VAC, at 25 C cold start 4000 VAC from input to output 1500 VAC from input to ground 500 VAC from output to ground MTBF: EMC Performance EN55011 / EN55022: FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: Class B conducted, class B radiated Class B conducted, class B radiated Class B conducted, class B radiated Harmonic distortion, class A and D Line flicker ESD, 8 KV air and 6 KV contact Radiated immunity, 3 V/m Fast transient/burst, 2 KV Surge, 1 KV diff., 2 KV com. Conducted immunity, 3 Vrms Magnetic field immunity, 3 A/m Voltage dips, 30% reduction for 500 ms 60% reduction for 100 ms >95% reduction for 10 ms 400,000 hours at full load at 25 C ambient, calculated per MIL-HDBK-217F o o OUTPUT SPECIFICATIONS Output voltage/current: Maximum output power: Ripple and noise: Overvoltage protection: See rating chart See rating chart 2% peak to peak on 5.0 V model, 1% peak to peak on other models. Provided on output #1 only; set at 112-132% of its nominal output voltage All outputs protected to short circuit conditions o All outputs 0.04% / C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 s after a 25% step load change Overcurrent protection: Temperature coefficient: Transient response: ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: -10 C to +70 C o o -40 C to +85 C 5% to 95% non-condensing o Derate from 100% at +50 C linearly to o 50% at +70 C o o EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: EN61000-4-11: Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com UNIVERSAL INPUT OUTPUT VOLTAGE/CURRENT RATING CHART Output #1 P/N Vnom Min.-Max.Current Min.-Max.Current Tol. at convection at forced air (2) TMC60 MEDICAL & ITE SERIES Output #2 Vnom Imin Imax Tol. Vnom Output #3 Imin Imax Tol. Maximum Output(3) Power 55 W 60 W 64 W 64 W 64 W 55 W 55 W 55 W 37.5 W TMC60-S05 5V TMC60-S12 12 V TMC60-S15 15 V TMC60-S24 24 V TMC60-S48 48 V TMC60-D23 +5 V TMC60-D25 +5 V TMC60-T31 +5 V TMC60-T31-3 +3.3 V TMC60-T31-5 +5 V TMC60-T32 +5 V TMC60-T39 +5 V NOTES: 1. 2. 3. 4. 0-11 A 0-5 A 0-4.3 A 0-2.7 A 0-1.35 A 0.5-6 A 0.5-6 A 0.5-6 A 0.8-6 A 0.5-6 A 0.5-6 A 0.5-6 A (N/A) (N/A) (N/A) (N/A) (N/A) 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 2% 2% 2% 2% 2% 3% 3% 3% 3% 3% 3% 3% +12 V +24 V +12 V +5.2 V +3.3 V +15 V +24 V (N/A) (N/A) (N/A) (N/A) (N/A) 0.1 A 3A 0.1 A 1.5 A 0.1 A 3A 0.1 A 3A 0A 1.5 A 0.1 A 2.4 A 0.1 A 1.5 A 5% 5% 5% 5% 5% 5% 5% -12 V +12 V +12 V -15 V -12 V (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A 4% 4% 4% 37.5/47.5W(4) 4% 55 W 4% 55 W Safety approvals are for PCB form only. To order unit with cover fitted, add suffix "C". Maximum current of output #1 of multi-output models can be 8 A at 5 CFM forced air provided by user. The maximum output power shown is convection rating. 47.5W with 5CFM forced air provide by user. MECHANICAL SPECIFICATIONS NOTES: 1. 2. 3. Dimensions shown in inches [mm] Tolerance 0.02 [0.5] maximum Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal.. Ground tab is 0.25 [6.35] x 0.032 [0.8]. To ensure compliance with level B emissions, connect the two "" marked mounting holes with metallic standoffs to chassis. Weight: 205 grams (0.45 lbs.) approx. 4. 5. 6. 7. PIN CHART PIN 1 MODEL 2 3 4 5 6 TMC60-S05 TMC60-S24 TMC60-D23 TMC60-T31 TMC60-S12 TMC60-S48 TMC60-D25 TMC60-T32 TMC60-S15 +V1 +V1 RTN RTN N.C. N.C. +V1 TMC60-T39 +V1 +V1 +V1 +V1 +V1 RTN RTN RTN RTN RTN RTN N.C. -V3 +V3 +V2 +V2 +V2 TMC60-T31-3 TMC60-T31-5 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com |
Price & Availability of TMC60-D23 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |